Kinetyx
Day 00 · InoculateTwin · 01 Model
Kinetyx. The living physics-ML digital twin of every bioprocess.
Kinetyx fits mechanistic bioprocess equations and data-driven surrogates to your own batches. The result is a twin that estimates what you cannot measure and simulates what has not happened yet.
Example Soft-sensor states at day 7, illustrative.
Day 02 · LagCapabilities
What it does.
01
Hybrid twin
Kinetics, metabolism and mass transfer, with learned terms where the equations fall short.
02
Soft sensors
Viable cells, metabolites and other unmeasured states, estimated between samples.
03
What-if rollouts
Thousands of feed and condition trajectories simulated per batch on GPUs.
04
Continuous calibration
New batches and assays refit the twin; its error is reported per variable.
05
Versioned twins
Every twin version, its data and its fit are recorded for review.
06
Twin API
The shared model that Titera, Sentyl, Feedra and Scalyx all query.
Day 04 · GrowthWhat if
Roll the batch forward before you run it.
Feed level
Temperature shift
- Harvest titer
- –
- Peak viable cells
- –
- Fixed recipe
- 3.05 g/L
Example Twelve rollouts of a toy culture model, precomputed. The dashed line is the fixed recipe. A real Kinetyx twin is calibrated to your cell line and process and runs thousands of rollouts.
Day 06 · GrowthHow it works
One run, start to finish.
01Day 1
Ingest
Historian, PAT and assays for one process.
02Weeks 1–3
Fit
Mechanistic core plus learned terms on past batches.
03Week 4
Test
Held-out batches score the twin variable by variable.
04Ongoing
Run
Live states every few minutes.
05Per batch
Refit
Each harvested batch updates the twin.
Day 08 · ProductionSpecification
The details.
| Item | Detail |
|---|---|
| Inputs | Process time series, PAT spectra, offline assays, batch phases |
| Model | Hybrid mechanistic and physics-ML surrogate (draft) |
| States | Viable and total cells, glucose, lactate, ammonia, titer and others per process |
| Rollouts | Thousands per batch on one GPU node (design target) |
| Versioning | Twin, data and fit recorded per version |
| Runs on | Modulus, BioNeMo priors, NVIDIA GPUs on-premises or dedicated cloud |
Day 10 · ProductionIn the loop
Where it sits.
Every harvested batch and its assaysrecalibrate the Kinetyx twin
Kinetyx is the twin the other five products use. Every batch any of them touches comes back to refit it.
Day 12 · Late productionQuestions
Straight answers.
Is the twin a black box?
No. The core is mechanistic, so states have physical meaning. Learned terms are bounded and reported, and every version can be inspected.
What if our process is unusual?
That is common. We start from the closest mechanistic template and let your data correct it; the reported error tells you how far to trust it.
Does it need new sensors?
No. It uses what you already measure. Better PAT data narrows its ranges.
Day 14 · HarvestNext step
Bring one process. We will twin it.
Share the batch records and PAT data from one process you run today. We calibrate a twin of it, forecast your next runs before they finish, and show you where yield and quality are being left in the vessel.